Mechanical APDL · 2024 R1
VAL3
Signature
VAL3, VAL4, VAL5, LDSTEP, SUBSTEP, FREQB, FREQE, PrintType, LogOpt Summary
APDL POST1 postprocessor command (VAL3) used in modeling or analysis workflows (Lab, PRES, PROT, PLAT).
Arguments
| Name | Description |
|---|---|
| Lab | Alphanumeric label or identifier. |
| PRES | PRES parameter for the POST1 command. |
| PROT | PROT parameter for the POST1 command. |
| PLAT | PLAT parameter for the POST1 command. |
| Option | Option parameter for the POST1 command. |
| Option Lab | Option Lab parameter for the POST1 command. |
| PHSC -- Pressure phase angle | PHSC -- Pressure phase angle parameter for the POST1 command. |
| SPLC -- Sound pressure level | SPLC -- Sound pressure level parameter for the POST1 command. |
| DGCT -- Acoustic directivity | DGCT -- Acoustic directivity parameter for the POST1 command. |
| PSCT -- Maximum scattered pressure | PSCT -- Maximum scattered pressure parameter for the POST1 command. |
| TSCT -- Target strength | TSCT -- Target strength parameter for the POST1 command. |
| PWL -- Sound power level | PWL -- Sound power level parameter for the POST1 command. |
| VAR1B, VAR1E | VAR1B, VAR1E parameter for the POST1 command. |
| NVAR1 | NVAR1 parameter for the POST1 command. |
| VAR2B, VAR2E | VAR2B, VAR2E parameter for the POST1 command. |
| NVAR2 | NVAR2 parameter for the POST1 command. |
| VAL1 | VAL1 parameter for the POST1 command. |
| VAL2 | VAL2 parameter for the POST1 command. |
| VAL3 | VAL3 parameter for the POST1 command. |
| VAL4 | VAL4 parameter for the POST1 command. |
| VAL5 | VAL5 parameter for the POST1 command. |
| LDSTEP | LDSTEP parameter for the POST1 command. |
| n | n parameter for the POST1 command. |
| ALL | ALL parameter for the POST1 command. |
| SUBSTEP | SUBSTEP parameter for the POST1 command. |
| n | n parameter for the POST1 command. |
| ALL | ALL parameter for the POST1 command. |
| FREQB | FREQB parameter for the POST1 command. |
| FREQE | FREQE parameter for the POST1 command. |
| PrintType | PrintType parameter for the POST1 command. |
| PLXY | PLXY parameter for the POST1 command. |
| PLYZ | PLYZ parameter for the POST1 command. |
| PLXZ | PLXZ parameter for the POST1 command. |
| SPHR | SPHR parameter for the POST1 command. |
| LogOpt | LogOpt parameter for the POST1 command. |
| OB0 | OB0 parameter for the POST1 command. |
| OB1 | OB1 parameter for the POST1 command. |
| OB2 | OB2 parameter for the POST1 command. |
| OB3 | OB3 parameter for the POST1 command. |
| OB6 | OB6 parameter for the POST1 command. |
| OB12 | OB12 parameter for the POST1 command. |
| OB24 | OB24 parameter for the POST1 command. |
Manual grouping
- POST1 : Special Purpose
This page summarizes syntax and usage in plain language. It does not replace official Ansys documentation. See the full command entry in Ansys Help (Ansys license required).